10Type plate for PicoR+ drives Type designation: e.g., P 9/16 R+P size of drive (tube diameter) P – 35 mm9/16 rated torque/output speedR electroni
11Drives for roller shuttersInformation on the PicoR+ drive PicoR+ drives with electronic limit switching detect and program the upper limit posit
12Programming the end positions for type PicoR+ 1. Programming the upper limit position First, travel the roller shutters towards the upper lim
13Drives for roller shutters3. Programming the travelling distance Travel the roller shutters towards the upper limit position again, without
14 R(+) drivesType plate for R(+) drives Type designation: e.g., R 8/17 R+R size of drive (tube diameter) P – 45 mm8/17 rated torque/output speedR
15Drives for roller shuttersInformation on the R(+) driveR(+) drives with electronic limit switching detect and program both limit positions automati
161. Programming the upper limit positionFirst, travel the roller shutters towards the upper limit position until the drive switches off au
17Drivesfor roller shutters1. Programming the upper limit positionFirst, travel the roller shutters towards the upper limit position until t
18Type plate for RP(+) drives Type designation: e.g., R 8/17RP+R size of drive (tube diameter) P – 45 mm8/17 rated torque/output speedP point to p
19Drives for roller shuttersInformation on the RP(+)drive RP(+) drives with electronic limit switch-ing detect and program both limit posi-tions au
2PrefaceUsing the installation manualThe installation manual describes the commissioning of Becker tubular drives for roller shutters and
20RP(+) drives 1. Programming the upper limit positionConnect the wires in the connecting cables of the drive to the wires of the same colour in
21Drivesfor roller shutters3. Deleting the limit positions via the programming unitPress the programming button and keep it pressed.Press the
22PR+ drives Type plate for PR+ drives Type designation: e.g., R 8/17 C PR+R size of drive (tube diameter) P – 35 mm R – 45 mm12/17 rated torque/ou
23Drives for roller shuttersInformation on the PR+ drive PR+ drives with electronic limit switch-ing detect and program the limit pos-ition
24PR+ drives Setting the limit positions with switches of type PR+1. Delete both limit positions with the switchesSet both switches to O and give a sh
25Drivesfor roller shuttersProgramming the limit positions with the programming unit of type PR+1. Setting the lower limit position with the programmi
26Type plate for PRF+ drives Type designation: e.g., R8/17 C PRF+R size of drive (tube diameter) P – 35 mm R – 45 mm8/17 rated torque/output speed
27Drives for roller shuttersInformation on the PRF+ drive PRF+ drives with electronic limit switch-ing detect and program the limit po-sitions
28Setting the limit positions for type PRF +3. Deleting the limit positions using the master transmitterPress the programming button and the STOP
29Drivesfor roller shuttersSetting the intermediate positions for type PRF +4. Programming the intermediate positionMove the drive to the require
3Controls for sun protectionControls for roller shuttersDrives for sun protectionRoller shuttersSun protectionDrives for roller shuttersContentsHow to
30Control unit SC431Programming the SC4311. Turn the housing cover (2 mm) clock-wise and remove it.Commissioning the radio-controlled light sensor SC
31Controls for roller shuttersSetting the sun protection1. Set the DIP switches 1 and 4 to ON. This activates the sun protection and the configurati
32How to identify the type of drive:The drives can be identified using the programming unit, even when they are installed. Connect the wire
33Drives for sun protectionTravel the curtain downwards and press the program-ming button again for 2 seconds.If the drive does not react or if it c
34Type plate for the M driveConnecting M drives Drives with mechanical limit switching must not be connected in parallel to a control sec
35Drives for sun protectionInformation on the M driveBefore installation, make sure that the drive adapter safety catch has engaged (is screwed o
36Setting the limit positions for M drives1. Setting the extending limit positionAfter the tube is installed, move the drive in the extending directio
37Drives for sun protectionSwitch off the retracting mechanism. Using the flexible tool, turn the ad-juster for the extending limit position 3-1
38S(+) drives Type plate for S(+) drives Type designation: e.g., R 20/17 S+R size of drive (tube diameter) R – 45 mm L – 58 mm20/17 rated torque/o
39Drives for sun protectionInformation on the S(+) driveS(+) drives with electronic limit switching detect and program the closing limit po-sition au
4Which type of roller shutter drive has been installed?How to identify the type of drive:GeneralIf the drive produces a loud noise and the tube
40Programming the limit positions with the program-ming unit of type S(+)1. Programming the extend-ing limit position via the programming unitConnect
41Drivesfor sun protection3. Deleting the limit positions using the programming unitPress the programming button on the programming unit until the
42PS(+) drives Type plate for PS(+) drives Type designation: e.g., R 30/17 C PS+R size of drive (tube diameter) P – 35 mm R – 45 mm L – 58 mm30/17
43Drives for sun protectionInformation on the PS(+) drive PS(+) drives with electronic limit switch-ing detect and program the closing limit position
44Setting the limit positions via the switches of type PS(+)1. Delete both limit positions with the switchesSet both switches to O and execute a short
45Drivesfor sun protectionProgramming the limit positions via the programming unit of type PS(+)1. Programming the extend-ing limit position with the
46SE-B(+) drives Type plate for SE-B(+) drives Type designation: e.g., R 40/17 SE-B+R size of drive (tube diameter) R – 45 mm L – 58 mm40/17 rated
47Drives for sun protectionInformation on the SE-B(+) drive SE-B(+) drives with electronic limit switching detect and program the clos-ing limit
48Programming the limit positions with the programming unit of type SE-B(+)1. Programming the extend-ing limit position with the programming unitConne
49Drives for sun protection3. Deleting the limit positions using the programming unitPress the programming button and keep it pressed.Press the
5Drives for roller shuttersIf the drive does not react, RF(+) drives with integrated radio receiver (up to 2002) or PRF+ drives (from 2003 onwards) h
50Type plate for PSF(+) drives Type designation: e.g., R30/17C PSF+R size of drive (tube diameter) P – 35 mm R – 45 mm L – 58 mm30/17 rated torque
51Drives for sun protectionInformation on the PSF(+) drive PSF(+) drives with electronic limit switching detect and program the re-tracting
52Setting the limit positions for type PSF(+)3. Deleting the limit positions via the master transmitterPress the programming button and the STOP
53Drivesfor sun protectionSetting the intermediate positions for type PSF(+)4. Programming intermediate position ITravel the curtain to the desired
54Commissioning the radio-controlled Sun-Wind-Set with handheld transmitter and SWS241 sensorSWS241 control set1. Programming the master transmittera
55Controls for sun protection2. Setting the sun thresholdUse the tool provided to turn the sun threshold regulator to the desired setting.
561. Programming the master transmitterSwitch off the power supply on the radio receiver (drive type PSF(+)) and then switch it back on . Press
57Controls for sun protection3. Setting the sun thresholdUse the tool provided to turn the sun threshold regulator to the desired setting.
581. Programming the master transmitterSwitch off the power supply on the radio receiver (drive type PSF(+)) and then switch it back on . Press
59Controls for sun protection0 = Off1 = Sensitive9 = Insensitive3. Setting the wind thresholdUse the tool provided to turn the wind threshold r
6Type plate for the M driveConnecting M drives Drives with mechanical limit switching must not be connected in parallel to a control sect
60Caution! Failure to observe these instructions can lead to serious injuries.Important safety instructions for handling tubular drives.• Do not allo
61• Disconnect the connecting cable from the power prior to installation.• Always comply with regulations of local energy supply companies and VDE 1
BECKER-Antriebe GmbHFriedrich-Ebert-Str. 2-4 35764 Sinn, GermanyTel.: +49 (0) 27 72/ 507-0 Fax: +49 (0) 27 72 / [email protected] www.be
7Drives for roller shuttersInformation on drive type MBefore installation, make sure that the drive adapter safety catch has engaged (is screwed
8Setting the limit positions for M drivesAfter the tube is installed, move the drive down-wards until it switches off automatically. Using t
9Drives for roller shuttersTravel the roller shutters upwards until the drive switches off automatically via the limit switch for the upper