Becker R12/17C Instrukcja Instalacji

Przeglądaj online lub pobierz Instrukcja Instalacji dla Nie Becker R12/17C. Becker R12/17C Installation manual [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 2 - Using the installation manual

10Type plate for PicoR+ drives Type designation: e.g., P 9/16 R+P size of drive (tube diameter) P – 35 mm9/16 rated torque/output speedR electroni

Strona 3 - Roller shuttersSun protection

11Drives for roller shuttersInformation on the PicoR+ drive PicoR+ drives with electronic limit switching detect and program the upper limit posit

Strona 4

12Programming the end positions for type PicoR+ 1. Programming the upper limit position First, travel the roller shutters towards the upper lim

Strona 5

13Drives for roller shutters3. Programming the travelling distance Travel the roller shutters towards the upper limit position again, without

Strona 6

14 R(+) drivesType plate for R(+) drives Type designation: e.g., R 8/17 R+R size of drive (tube diameter) P – 45 mm8/17 rated torque/output speedR

Strona 7 - Information on drive type M

15Drives for roller shuttersInformation on the R(+) driveR(+) drives with electronic limit switching detect and program both limit positions automati

Strona 8

161. Programming the upper limit positionFirst, travel the roller shutters towards the upper limit position until the drive switches off au

Strona 9

17Drivesfor roller shutters1. Programming the upper limit positionFirst, travel the roller shutters towards the upper limit position until t

Strona 10 - PicoR+ drives

18Type plate for RP(+) drives Type designation: e.g., R 8/17RP+R size of drive (tube diameter) P – 45 mm8/17 rated torque/output speedP point to p

Strona 11

19Drives for roller shuttersInformation on the RP(+)drive RP(+) drives with electronic limit switch-ing detect and program both limit posi-tions au

Strona 12

2PrefaceUsing the installation manualThe installation manual describes the commissioning of Becker tubular drives for roller shutters and

Strona 13

20RP(+) drives 1. Programming the upper limit positionConnect the wires in the connecting cables of the drive to the wires of the same colour in

Strona 14 - R(+) drives

21Drivesfor roller shutters3. Deleting the limit positions via the programming unitPress the programming button and keep it pressed.Press the

Strona 15 - Information on the R(+) drive

22PR+ drives Type plate for PR+ drives Type designation: e.g., R 8/17 C PR+R size of drive (tube diameter) P – 35 mm R – 45 mm12/17 rated torque/ou

Strona 16 - R(+) drives

23Drives for roller shuttersInformation on the PR+ drive PR+ drives with electronic limit switch-ing detect and program the limit pos-ition

Strona 17 - 2 x click

24PR+ drives Setting the limit positions with switches of type PR+1. Delete both limit positions with the switchesSet both switches to O and give a sh

Strona 18 - RP(+) drives

25Drivesfor roller shuttersProgramming the limit positions with the programming unit of type PR+1. Setting the lower limit position with the programmi

Strona 19

26Type plate for PRF+ drives Type designation: e.g., R8/17 C PRF+R size of drive (tube diameter) P – 35 mm R – 45 mm8/17 rated torque/output speed

Strona 20

27Drives for roller shuttersInformation on the PRF+ drive PRF+ drives with electronic limit switch-ing detect and program the limit po-sitions

Strona 21 - 3 x click

28Setting the limit positions for type PRF +3. Deleting the limit positions using the master transmitterPress the programming button and the STOP

Strona 22 - PR+ drives

29Drivesfor roller shuttersSetting the intermediate positions for type PRF +4. Programming the intermediate positionMove the drive to the require

Strona 23 - Information on the PR+ drive

3Controls for sun protectionControls for roller shuttersDrives for sun protectionRoller shuttersSun protectionDrives for roller shuttersContentsHow to

Strona 24

30Control unit SC431Programming the SC4311. Turn the housing cover (2 mm) clock-wise and remove it.Commissioning the radio-controlled light sensor SC

Strona 25 - 1 x click

31Controls for roller shuttersSetting the sun protection1. Set the DIP switches 1 and 4 to ON. This activates the sun protection and the configurati

Strona 26 - PRF+ drives

32How to identify the type of drive:The drives can be identified using the programming unit, even when they are installed. Connect the wire

Strona 27 - Correcting the direction

33Drives for sun protectionTravel the curtain downwards and press the program-ming button again for 2 seconds.If the drive does not react or if it c

Strona 28 - PRF+ drives

34Type plate for the M driveConnecting M drives Drives with mechanical limit switching must not be connected in parallel to a control sec

Strona 29 - 2 x click 2 x click

35Drives for sun protectionInformation on the M driveBefore installation, make sure that the drive adapter safety catch has engaged (is screwed o

Strona 30 - Control unit SC431

36Setting the limit positions for M drives1. Setting the extending limit positionAfter the tube is installed, move the drive in the extending directio

Strona 31 - Controls

37Drives for sun protectionSwitch off the retracting mechanism. Using the flexible tool, turn the ad-juster for the extending limit position 3-1

Strona 32 - Possible drive types:

38S(+) drives Type plate for S(+) drives Type designation: e.g., R 20/17 S+R size of drive (tube diameter) R – 45 mm L – 58 mm20/17 rated torque/o

Strona 33

39Drives for sun protectionInformation on the S(+) driveS(+) drives with electronic limit switching detect and program the closing limit po-sition au

Strona 34 - M drives

4Which type of roller shutter drive has been installed?How to identify the type of drive:GeneralIf the drive produces a loud noise and the tube

Strona 35 - Information on the M drive

40Programming the limit positions with the program-ming unit of type S(+)1. Programming the extend-ing limit position via the programming unitConnect

Strona 36

41Drivesfor sun protection3. Deleting the limit positions using the programming unitPress the programming button on the programming unit until the

Strona 37

42PS(+) drives Type plate for PS(+) drives Type designation: e.g., R 30/17 C PS+R size of drive (tube diameter) P – 35 mm R – 45 mm L – 58 mm30/17

Strona 38 - S(+) drives

43Drives for sun protectionInformation on the PS(+) drive PS(+) drives with electronic limit switch-ing detect and program the closing limit position

Strona 39 - S+ drives

44Setting the limit positions via the switches of type PS(+)1. Delete both limit positions with the switchesSet both switches to O and execute a short

Strona 40

45Drivesfor sun protectionProgramming the limit positions via the programming unit of type PS(+)1. Programming the extend-ing limit position with the

Strona 41

46SE-B(+) drives Type plate for SE-B(+) drives Type designation: e.g., R 40/17 SE-B+R size of drive (tube diameter) R – 45 mm L – 58 mm40/17 rated

Strona 42 - PS(+) drives

47Drives for sun protectionInformation on the SE-B(+) drive SE-B(+) drives with electronic limit switching detect and program the clos-ing limit

Strona 43 - PS+ drives

48Programming the limit positions with the programming unit of type SE-B(+)1. Programming the extend-ing limit position with the programming unitConne

Strona 44

49Drives for sun protection3. Deleting the limit positions using the programming unitPress the programming button and keep it pressed.Press the

Strona 45

5Drives for roller shuttersIf the drive does not react, RF(+) drives with integrated radio receiver (up to 2002) or PRF+ drives (from 2003 onwards) h

Strona 46 - SE-B(+) drives

50Type plate for PSF(+) drives Type designation: e.g., R30/17C PSF+R size of drive (tube diameter) P – 35 mm R – 45 mm L – 58 mm30/17 rated torque

Strona 47 - SE-B+ drives

51Drives for sun protectionInformation on the PSF(+) drive PSF(+) drives with electronic limit switching detect and program the re-tracting

Strona 48

52Setting the limit positions for type PSF(+)3. Deleting the limit positions via the master transmitterPress the programming button and the STOP

Strona 49

53Drivesfor sun protectionSetting the intermediate positions for type PSF(+)4. Programming intermediate position ITravel the curtain to the desired

Strona 50 - PSF(+) drives

54Commissioning the radio-controlled Sun-Wind-Set with handheld transmitter and SWS241 sensorSWS241 control set1. Programming the master transmittera

Strona 51 - PSF+ drives

55Controls for sun protection2. Setting the sun thresholdUse the tool provided to turn the sun threshold regulator to the desired setting.

Strona 52 - PSF(+) drives

561. Programming the master transmitterSwitch off the power supply on the radio receiver (drive type PSF(+)) and then switch it back on . Press

Strona 53 - 2 x click2 x click

57Controls for sun protection3. Setting the sun thresholdUse the tool provided to turn the sun threshold regulator to the desired setting.

Strona 54 - SWS241 control set

581. Programming the master transmitterSwitch off the power supply on the radio receiver (drive type PSF(+)) and then switch it back on . Press

Strona 55

59Controls for sun protection0 = Off1 = Sensitive9 = Insensitive3. Setting the wind thresholdUse the tool provided to turn the wind threshold r

Strona 56 - SWS441/SWS641 control set

6Type plate for the M driveConnecting M drives Drives with mechanical limit switching must not be connected in parallel to a control sect

Strona 57

60Caution! Failure to observe these instructions can lead to serious injuries.Important safety instructions for handling tubular drives.• Do not allo

Strona 58 - SC211 control

61• Disconnect the connecting cable from the power prior to installation.• Always comply with regulations of local energy supply companies and VDE 1

Strona 59

BECKER-Antriebe GmbHFriedrich-Ebert-Str. 2-4 35764 Sinn, GermanyTel.: +49 (0) 27 72/ 507-0 Fax: +49 (0) 27 72 / [email protected] www.be

Strona 60 - Important safety instructions

7Drives for roller shuttersInformation on drive type MBefore installation, make sure that the drive adapter safety catch has engaged (is screwed

Strona 61

8Setting the limit positions for M drivesAfter the tube is installed, move the drive down-wards until it switches off automatically. Using t

Strona 62

9Drives for roller shuttersTravel the roller shutters upwards until the drive switches off automatically via the limit switch for the upper

Komentarze do niniejszej Instrukcji

Brak uwag